The Pak-Track products are designed to record various types of information including temperature, humidity, vibration, shock, light intensity, pressure, time and date, and GPS locations of events.
Pak-Track web-application provides the user with various analytics such as data over time graphs, constructive PSD graphs for vibration data, drop height, and face and edge detection for shock data.
Each Pak-Track device can monitor a variety of hazards. The hazards are recorded either periodically or when an event occurs. The events are determined based on user define thresholds allowing for customizable recording.
Temperature can be recorded periodically or when the temperature exceeds either a high or low threshold.
Measurement Range |
-40 °C – 85 °C |
Accuracy |
±0.4 °C |
Resolution |
14 bit |
Measurement Interval |
0 s to 65535 s |
Trigger Events |
Interval High Threshold Low Threshold |
Humidity can be recorded periodically or when the humidity exceeds either a high or low threshold.
Measurement Range |
0 %RH to 100 %RH |
Accuracy |
±3 %RH |
Resolution |
12 bit |
Measurement Interval |
0 s to 65535 s |
Trigger Events |
Interval High Threshold Low Threshold |
Vibration can be recorded periodically or when the vibration surpasses an RMS threshold.
Measurement Range |
±16 G |
Accuracy |
±0.03125 G |
Resolution |
8 bit |
Measurement Interval |
0 s to 65535 s |
Trigger Events |
Interval RMS Threshold |
Sampling Rate |
1600 Hz |
Sample Size |
2048 Bytes |
Frequency Range |
1 Hz to 3200 Hz |
Shock can be recorded when the Pak-Track device detects an impact or a drop.
Measurement Range |
±200 G |
Accuracy |
±0.64 G |
Resolution |
8 bit |
Measurement Interval |
N/A |
Trigger Events |
Free-Fall Instantaneous |
Sampling Rate |
1600 Hz |
Sample Size |
1024 Bytes |
Frequency Range |
1 Hz to 3200 Hz |
Pressure can be recorded when there is a change in pressure from atmospheric pressure.
Measurement Range |
20 kPa to 110 kPa |
Accuracy |
±0.25 kPa |
Resolution |
20 bit |
Measurement Interval |
0 s to 65535 s |
Trigger Events |
Interval High Threshold Change Over Time |
Light luminance level is recorded
Measurement Range |
0 lux to 34197 lux |
Accuracy |
±0.5218 lux |
Resolution |
16 bit |
Measurement Interval |
0 s to 65535 s |
Trigger Events |
Interval High Threshold Low Threshold |
Small enough to fit anywhere, gather data in Real-Time and view on website
*Measurements shown are in millimeters (mm)
Multiple end devices can communicate with a coordinator system that receives and uploads the data to the website where the user can view the information in real-time. Each unit is rechargeable and can last for up to a month.
The Pak-Track II is a stand alone product that records all of the sensor data to onboard memory.
|
Pak-Track I (Real Time) |
Pak-Track II |
Pak-Track III |
Operating Temperature Range |
-40 °C – 85 °C |
-40 °C – 85 °C |
-40 °C – 85 °C |
Size |
82.55 X 48.20 X 21.16 mm |
82.55 X 48.20 X 21.16 mm |
82.55 X 48.20 X 21.16 mm |
Weight |
50 g |
50 g |
100 g |
Battery Life |
Up to 45 days |
Up to 45 days |
Up to 45 days |
Life Expectancy |
2 years |
2 years |
2 years |
Onboard Data Storage |
2 GB |
2 GB |
2 GB |
Real-Time Updates |
Yes |
No |
Yes |
Tablet Required |
Yes |
No |
No |
Data is available for analysis immediately with all pre-processing. All you need is a browser with an internet connection to access data.
Each device had a unique ID number and its current operating settings.
Provides important updates regarding the device.
Provides a map showing the locations and times of where triggered events took place.
Shows the accumulated data for each sensor in a simple data over time format.
Calculates the height that the device fell from when a free-fall event was triggered.
Calculates the orientation that the device was in when a shock event occurred.
Calculates a PSD graph of the vibration events.
1 Lomb Memorial Dr, Rochester, NY 14623, United States